We carry Lascar Electronic’s range of stand-alone and real-time USB data loggers. It can measure and record a variety of parameters such as temperature, relative humidity, voltage, event, current, and carbon monoxide.
Simply insert any of these data loggers into your computer’s USB port. Which you can then name it, choose your sampling rate, and set high and low alarms. Logged data is viewed via Lascar’s free configuration and analysis software available with any data logger.
Our data loggers are used in a variety of applications where monitoring and logging of data is required, some examples of such applications include:
The EL DataPad is engineered to give users better convenience by allowing the users to view the data recorded by the data loggers by simply plugging the data loggers into EL Datapad without the use of computers.
The EL-DataPad is compatible with the following USB Data Loggers:
EL-USB-1, EL-USB-1-LCD, EL-USB-1-PRO, EL-USB-2, EL-USB-2+, EL-USB-2-LCD,
EL-USB-2-LCD+, EL-USB-TC, EL-USB-TC-LCD, EL-USB-LITE.
It is not compatible with the following EL-USB Data Loggers:
EL-USB-1-RCG, EL-USB-3, EL-USB-4, ELUSB-5, EL-USB-CO, EL-USB-CO300.
Measurement Range | -35 to +80°C / -31 to + 176°F |
Accuracy (overall error) | +/- 0.5°C typical |
Readings | 16,382 |
Logging Rate | User selectable between 10 seconds and 12 hours |
Battery Life | 3 Years |
Measurement Range | -35 to +80°C / -31 to + 176°F |
Accuracy (overall error) | +/- 0.5°C typical |
Readings | 16,382 |
Logging Rate | User selectable between 10 seconds and 12 hours |
Battery Life | 2 years (at 25°C and 1 minute logging rate, LCD on) |
Measurement Range | -40 to +125°C / -40 to +257°F |
Accuracy (overall error) | ±0.2°C / ±0.4°F |
Readings | 32,510 |
Logging Rate | User selectable between 10 seconds and 12 hours |
Battery Life | 2 Years |
Measurement Range | -20 to +60°C / -4 to +140°F |
Accuracy (overall error) | ±1°C / ±2°F |
Readings | 32,510 |
Logging Rate | User selectable between 10 seconds and 12 hours |
Battery Life | 4 Weeks |
Temperature & RH Range | -35°C to 80°C | 0 to 100%RH |
Internal resolution | 0.5°C (1°F) | 0.5%RH |
Accuracy | 0.45°C (0.86°F) typical (5 to 60°C) | 2.05%RH typical (10 to 90%RH) |
Long term stability | <0.02°C (0.04°F) | <0.25%RH per year |
Logging Rate | Selectable between 10 seconds and 12 hours |
|
Battery Life | 3 Years |
Temperature & RH Range | -35°C to 80°C | 0 to 100%RH |
Internal resolution | 0.5°C (1°F) | 0.5%RH |
Accuracy | 0.45°C (0.86°F) typical (5 to 60°C) | 2.05%RH typical (10 to 90%RH) |
Long term stability | <0.02°C (0.04°F) / year | <0.25%RH / year |
Logging Rate | Selectable between 10 seconds and 12 hours |
|
Battery Life | 3 Years |
Temperature & RH Range | -35°C to 80°C | 0 to 100%RH |
Internal resolution | 0.5°C (1°F) | 0.5%RH |
Accuracy | 0.45°C (0.86°F) typical (5 to 60°C) | 2.05%RH typical (10 to 90%RH) |
Long term stability | <0.02°C (0.04°F) | <0.25%RH per year |
Logging Rate | Selectable between 10 seconds and 12 hours |
|
Battery Life | 3 Years |
Temperature & RH Range | -35°C to 80°C | 0 to 100%RH |
Internal resolution | 0.5°C (1°F) | 0.5%RH |
Accuracy | 0.45°C (0.86°F) typical (5 to 60°C) | 2.05%RH typical (10 to 90%RH) |
Long term stability | <0.02°C (0.04°F) / year | <0.25%RH / year |
Logging Rate | Selectable between 10 seconds and 12 hours |
|
Battery Life | 3 Years |
Measurement Range | -10 to +50°C (+14 to +122°F) |
Accuracy | ±2.5°C (±4.5°F) |
Logging Rate | Every 30 minutes |
Battery Life | 1 month |
Measurement Range | 0 to 30V d.c. |
Accuracy | ±1% |
Logging Rate | User selectable between 1 second and 12 hours |
Battery Life | 3 Years |
Readings | 32,510 |
Measurement Range | 4 to 20mA d.c. |
Readings | 32,510 |
Accuracy | ±1% |
Battery Life | 3 Years (at 25°C and 2 second logging rate) |
Readings | 32,510 |
Operating Temperature Range | -35 to +80°C (-31 to +176°F) |
Maximum Event / State Change Frequency | 2Hz |
Maximum Count / Count Per Frequency | 100Hz |
Minimum time in State | 100ms |
Input Voltage Range | 3 to 28V d.c. |
Battery Life | 1 Year |
Maximum Event / State Change Frequency | 2Hz |
Maximum Count / Count Per Frequency | 100Hz |
Minimum time in State | 100ms |
Input Voltage Range | 3 to 28V d.c. |
Battery Life | 1 Year |
Measurement Range | 3 to 1000ppm CO |
Accuracy | ±7ppm CO |
Readings | 32,510 |
Logging Rate | User selectable between 10 seconds and 5 mins |
Battery Life | 3 Months |
Measurement range | -10 to 60°C (14 to 140°F) | 0 to 100%RH |
Accuracy | ±1.5°C (±3°F) | ±4.5% RH |
Operating temperature | -10 to 60°C (14 to 140°F) |
|
Battery | Not required |
Measurement Range K Type | 0 to +200°C (+32 to +392°F) |
Accuracy (thermocouple error not included) | ±1°C (±2°F) |
Readings | 32,510 |
Logging Rate | 1 second and 12 hours |
Battery Life | 2 Years |
Calibration Certificate | Available Seperately |
Measurement Range K Type | 0 to +200°C (+32 to +392°F) |
Accuracy (thermocouple error not included) | ±1°C (±2°F) |
Readings | 32,510 |
Logging Rate | 1 second and 12 hours |
Battery Life | 2 Years |
Calibration Certificate | Available Seperately |