The EL-GFX series is the most advanced data logger with display in Lascar’s range. EL-GFX is the first data logger with a display. This USB Data Logger range provides users with more real-time information than any other data logger on the market. These data logger includes a temperature data logger, a temperature and humidity data logger, and a dual-channel thermocouple data logger.
The EL-GFX Data Loggers are used in a variety of applications. These includes temperature and humidity monitoring or when logging of data is required. Some examples include:
The EL-GFX-1 USB data logger records over 250,000 temperature readings in one or more sessions for up to 1 year. It has a programmable audible alarm with visible alarm LEDs. It uses a IP67 case (waterproof) with buttons and a display with on-screen menus that provide real-time data like graphs.
EasyLog software enables quick configuration and data download via the USB port. Supplied with two batteries, USB cover, Mounting Clip and Micro USB cable.
Measurement Range | -30 to 80°C (-22 to 176°F) |
Accuracy (overall error) | ±0.2°C (±0.4°F) typical |
Operating temperature | -30 to 80°C (-22 to 176°F) |
Logging rate | User selectable between 10 seconds and 1 hour |
Calibration certificate | Available Separately |
The EL-GFX-2 USB data logger records over 250,000 temperature and humidity readings in one or more sessions for up to 1 year. It has a programmable audible alarm with visible alarm LEDs. It uses a IP67 case (waterproof) with buttons and a display with on-screen menus that provide real-time data like graphs.
EasyLog software enables quick configuration and data download via the USB port. Supplied with two batteries, USB cover, Mounting Clip and Micro USB cable.
Temperature & RH Range | -30°C to 80°C | 0 to 100%RH |
Internal Resolution | 0.1°C | 0.1%RH |
Accuracy | ± 0.35°C | 2.05%RH |
Long Term Stability | <0.02°C / year | <0.25%RH / year |
Logging Rate | User selectable between 10 seconds and 1 hour |
The EL-GFX-2+ High Accuracy USB data logger records over 250,000 temperature and humidity readings in one or more sessions for up to 1 year. It has a programmable audible alarm with visible alarm LEDs. It uses a IP67 case (waterproof) with buttons and a display with on-screen menus that provide real-time data like graphs.
EasyLog software enables quick configuration and data download via the USB port. Supplied with two batteries, USB cover, Mounting Clip and Micro USB cable.
Temperature & RH Range | -30°C to 80°C | 0 to 100%RH |
Internal Resolution | 0.1°C | 0.1%RH |
Accuracy | ± 0.25°C | ± 1.85%RH |
Long Term Stability | <0.02°C / year | <0.25%RH / year |
Logging Rate | User selectable between 10 seconds and 1 hour |
The EL-GFX-TC Thermocouple Data Logger with Graphic Screen records over 250,000 temperature and humidity readings in one or more sessions for up to 1 year. It has a programmable audible alarm with visible alarm LEDs. It uses a IP67 case (waterproof) with buttons and a display with on-screen menus that provide real-time data like graphs.
EasyLog software enables quick configuration and data download via the USB port. Supplied with K-type probe and batteries, the EL-GFX-TC is a popular part. It is also compatible with K, J and T-type thermocouples.
Measurement Range K Type (provided) | 0 to +200°C (+32 to +392°F) |
Accuracy (thermocouple error not included) | ±1°C (±2°F) |
Operating Temperature | -10 to +40°C (-14 to +104°F) |
Logging Rate | Selectable between 2 seconds and 1 hour |
Calibration Certificate | Available Separately |
The EL-GFX-DTC Dual Thermocouple Data Logger records over 250,000 temperature readings per channel in one or more sessions for up to 4 months. It has user-programmable audible alarm thresholds with highly visible confidence/alarm LEDs.
It is compatible with K, J and T-type thermocouples. Inside the rugged case, buttons for start, stop and restart and a graphic LCD with on-screen menus provide real-time analysis of data as a summary or as a graph. EL-WIN-USB enables quick configuration and data download via the USB port. Supplied with batteries, two K-type thermocouples and a magnetic wall mount the EL-GFX-DTC is a popular part.
Measurement Range K Type (provided) | 0 to +200°C (+32 to +392°F) |
Accuracy (thermocouple error not included) | ±1°C (±2°F) |
Operating Temperature | -10 to +40°C (-14 to +104°F) |
Logging Rate | Selectable between 2 seconds and 1 hour |
Calibration Certificate | Available Separately |
Dual Thermocouple Data Logger with Graphic LCD
The EL-GFX-DTC Dual Thermocouple Data Logger records over 250,000 temperature readings per channel in one or more sessions for up to 4 months. It has user-programmable audible alarm thresholds with highly visible confidence/alarm LEDs.
It is compatible with K, J and T-type thermocouples. Inside the rugged case, buttons for start, stop and restart and a graphic LCD with on-screen menus provide real-time analysis of data as a summary or as a graph. EL-WIN-USB enables quick configuration and data download via the USB port. Supplied with batteries, two K-type thermocouples and a magnetic wall mount the EL-GFX-DTC is a popular part.
Measurement Range | -30 to +80ºC | 0 to 100%RH |
Accuracy (overall error) | ±0.3ºC (±0.6ºF) | ±2.05%RH typical (20 to 80%RH) |
Resolution | 0.1ºC (0.2ºF) | ±0.1%RH |
Dew Point Accuracy | ±1.1ºC (±2.0ºF) typical |
|
Probe Cable Length | 2m (only one probe supplied) |
|
Battery Life | 1 year |
Dual Channel Thermistor Data Logger
This USB data logger records over 250,000 temperature readings per channel in one or more sessions for up to 4 months. It has user-programmable audible alarm thresholds with highly visible confidence/alarm LEDs.
Inside the rugged case, buttons for start, stop and restart and a graphic LCD with on-screen menus provide real-time analysis of data as a summary or as a graph. EL-WIN-USB enables quick configuration and data download via the USB port. Supplied with two thermistor probes and batteries, the EL-GFX-DTP is a popular part.
Measurement range | -40 to 125°C (-40 to 257°F) |
Logger accuracy (overall error) | ±0.1°C (±0.2°F) |
Operating temperature | -10 to 40°C (14 to 104°F) |
Logging rate | User selectable between 2 seconds and 1 hour |
Calibration certificate | Available Separately |
Probe Cable Length | 1m (39.4″) |
High Accuracy Dual Channel Thermistor Data Logger
This high accuracy USB data logger records over 250,000 temperature readings per channel in one or more sessions for up to 4 months. It has user-programmable audible alarm thresholds with highly visible confidence/alarm LEDs.
Inside the rugged case, buttons for start, stop and restart and a graphic LCD with on-screen menus provide real-time analysis of data as a summary or as a graph. EL-WIN-USB enables quick configuration and data download via the USB port. Supplied with two thermistor probes and batteries, the EL-GFX-DTP+ is a popular part.
Measurement range | -40 to 125°C (-40 to 257°F) |
Logger accuracy (overall error) | ±0.1°C (±0.2°F) |
Operating temperature | -10 to 40°C (14 to 104°F) |
Logging rate | User selectable between 2 seconds and 1 hour |
Calibration certificate | Available Separately |
Probe Cable Length | 3m (118.1″) |
Dual Channel GFX Vaccine Monitoring Kit
The EL-GFX-VAC2 is a vaccine monitoring kit combining a USB dual channel data logger with two glycol bottle probes. The unit stores over 250,000 readings, has an on-screen display showing max, min and last log as well as an on-board graph of the data collected.
Buttons allow the user to start, stop and restart the logger in the field and alarm breaches can be registered with both LED and audible alarms. The logger can be battery powered or used with a USB wall adaptor. Two channels allow measurement of two areas of a refrigerator or a refrigerator and freezer at the same time.
This product meets and exceeds CDC standards for vaccine monitoring.
Measurement range | -40 to 60°C (-40 to 140°F) |
Logger accuracy (overall error) | ±0.1°C (±0.2°F) |
Operating temperature | -10 to 40°C (14 to 104°F) |
Logging rate | User selectable between 2 seconds and 1 hour |
Calibration certificate | Supplied at 2 and 8°C |